TRUNK SPECIFICATIONS
TRUNK CIRCUIT SPECIFICATIONS
TYPE
PACK
Central
TN747
Capacity:8 Circuits
Office (CO)
Transmission: 1-Way In, 1-Way Out, or
2-Way 2-Wire 600 Ohms or
RC Balance Network
Signaling: Ground Start or Loop Start
Auxiliary
TN763 Capacity: 4 Circuits
Trunk
Transmission: 1-Way In, 1-Way Out,
or 2-Way 2-Wire
Signaling: Loop Start on Tip and Ring;
Two Additional Pairs Provide Seizure
and Answer Supervision and/or Make
Busy Information
Direct Inward
TN753
Capacity: 8 Circuits
Dialing (DID)
Transmission: 1-Way Incoming Fixed
Impedance to DID Trunk
Signaling: Wink or Immediate Start
Accepts Touch-Tone Dialing
Tie Trunk
TN760
Capacity: 4 Circuits
Transmission: 4-Wire Tip and Ring
Signaling: E&M signaling.
DS1 Trunk
TN722 Capacity: 24 Trunks for Voice Grade
Service 23 Trunks for Alternate
Voice/Data Service or DMI, One Trunk
Used for Signaling.
Mode: Multiplexes 24 or 23 Trunks
onto 1 Facility and Demultiplexes 1
Facility into 24 or 23 Trunks
Speed: Trunks at 64 kbps,
1 Facility at 1.544 Mbps
Signaling: DS1 Over 4-Wire