EQUIPMENT AND MAXIMUM
CABLING DISTANCES
EQUIPMENT
24-G
26-G
WIRE
WIRE
(FEET)
(FEET)
Attendant Console 2400
1500
Powered from Switch
350 350
510D or 515 Terminals 3000
2200
513 or 610 BCT, 4410 or 4425 terminals,
and 615 MT
(See Data Module or EIA Interface)
Max distance from terminal to
--
Module or ADU is 50 feet.
Data Modules:
Z702AL1-DSU Data Module Base
5000
4000
Z703AL1-DSU Data Module Base
5000
4000
7404D Data Module
5000 4000
Digital Terminal Data Module
3400
2200
(Modular) Processor Data Module
5000
4000
(Modular) Trunk Data Module
5000
4000
3270 Data Module
5000
4000
EIA Interface (Data Line Circuit
Pack and ADU):
19.2 kbps
2000
2000
9.6 kbps
5000 4000
4.8 kbps
7000
6000
2.4 kbps
12000 10000
1.2 kbps
20000 16000
0.3 kbps
40000 30000
Voice Terminals:
Analog Line—8 Ports (TN742, TN769)
or 16 Ports (TN785)
(On-Premises or
Out-of-Building—Same Premises)
500 or 2500 Type (See Note 1)
20000 13000
500 or 2500 Type (See Notes 1 and 2)
15000
9500
7100 Series
15200 10000
7100 Series (See Note 2)
10500
7000
Note 1: Only AT&T 500- or 2500-type terminals can be used off-
premises through a Central Office.
Note 2: These distances are for battery backup (worst case).
Page 6